MSD Ignition MSD7531 Digital 7 Plus Universal CDI Ignition Controller

Digital 7 Plus Universal CDI Ignition Controller

Skip to product information
1 of 2
MSD Ignition Part No. MSD7531
Sale Sold out
Taxes included. Shipping calculated at checkout.

SKU:MSD7531

Expert Advice Talk to real engine builders
Fast Dispatch Australia Wide Shipping
Family Owned Trusted since 1988
Secure Checkout Safe & Encrypted Payments
Quantity
✔ Secure Checkout
✔ Easy Returns
✔ Need Help? Call (02) 6025 5666
Contact us for ETA or alternative options View full details

Product Information

These Programmable Digital-7 CD Plus ignitions from MSD have an output power and Individual Cylinder Management timing system that are hard to beat. At the heart of these ignitions is a 15 MHz micro-controller that analyzes and manages every trigger signal. Their capacitive discharge circuits and state-of-the-art IGBT coil drivers work together to deliver a potent spark that can easily handle high cylinder pressures. Below 3,300 rpm, a series of sparks burn in the cylinder over 20 degrees of crankshaft rotation, producing a smooth idle with great throttle response. You can control all of this spark energy through an array of timing and rpm programs. These programs include: Individual cylinder timing that can program up to 10 degrees per cylinder in .1 degree increments, a launch retard that lets you retard the timing up to 15 degrees for 0-2.5 seconds after the launch, a launch timing curve, and a run curve enabling you to plot a timing curve in .1 degree increments per 100 rpm. They also feature a three-step retard, a gear retard that can retard timing up to 5 degrees with every gear change, a start retard, three rev limiters, a shift light, and an rpm-activated window switch. You can also map a complete timing curve for every gear, set stage retards to ramp timing, see updated X-Y plots with interpolation for smooth changes, view all ignition events in a new Launch History window, acquire 20 seconds of run data including two seconds prior to launch, program an rpm that is ramped in during the launch, and select vacuum advance and boost retard through a MAP sensor. They can be used on 4, 6, or 8-cylinder engines, and are supplied with the Pro-Data Plus software, PC harness, vibrations mounts, and wiring. An optional hand-held MSD Programmer Monitor is available separately.



Ignition Box Output Capacitive discharge
Circuitry Digital
Rev Limiter Yes
Timing Retard Three-stage
Data Acquisition No
CD Voltage Output to Coil 535 V
Current Draw 1.1 amps per 1,000 rpm
Spark Output (millijoules) 190 Millijoules
Minimum Operating Voltage 12 V
Maximum Operating Voltage 18 V
Length (in) 9.500 in.
Height (in) 2.250 in.
Width (in) 4.500 in.
Ignition Box Color Gold
Coil Included No
Warranty 1-year
Quantity Sold individually.
Notes Requires MAP sensor for the boost circuit.

Product Information

These Programmable Digital-7 CD Plus ignitions from MSD have an output power and Individual Cylinder Management timing system that are hard to beat. At the heart of these ignitions is a 15 MHz micro-controller that analyzes and manages every trigger signal. Their capacitive discharge circuits and state-of-the-art IGBT coil drivers work together to deliver a potent spark that can easily handle high cylinder pressures. Below 3,300 rpm, a series of sparks burn in the cylinder over 20 degrees of crankshaft rotation, producing a smooth idle with great throttle response. You can control all of this spark energy through an array of timing and rpm programs. These programs include: Individual cylinder timing that can program up to 10 degrees per cylinder in .1 degree increments, a launch retard that lets you retard the timing up to 15 degrees for 0-2.5 seconds after the launch, a launch timing curve, and a run curve enabling you to plot a timing curve in .1 degree increments per 100 rpm. They also feature a three-step retard, a gear retard that can retard timing up to 5 degrees with every gear change, a start retard, three rev limiters, a shift light, and an rpm-activated window switch. You can also map a complete timing curve for every gear, set stage retards to ramp timing, see updated X-Y plots with interpolation for smooth changes, view all ignition events in a new Launch History window, acquire 20 seconds of run data including two seconds prior to launch, program an rpm that is ramped in during the launch, and select vacuum advance and boost retard through a MAP sensor. They can be used on 4, 6, or 8-cylinder engines, and are supplied with the Pro-Data Plus software, PC harness, vibrations mounts, and wiring. An optional hand-held MSD Programmer Monitor is available separately.



Ignition Box Output Capacitive discharge
Circuitry Digital
Rev Limiter Yes
Timing Retard Three-stage
Data Acquisition No
CD Voltage Output to Coil 535 V
Current Draw 1.1 amps per 1,000 rpm
Spark Output (millijoules) 190 Millijoules
Minimum Operating Voltage 12 V
Maximum Operating Voltage 18 V
Length (in) 9.500 in.
Height (in) 2.250 in.
Width (in) 4.500 in.
Ignition Box Color Gold
Coil Included No
Warranty 1-year
Quantity Sold individually.
Notes Requires MAP sensor for the boost circuit.

Technical Information

Features

Genuine performance part backed by Engine Master Australia.

Specifications
Manufacturer
MSD Ignition
MPN
Not provided
UPC
085132075317
Our Part Number
MSD7531

Contact our team for specifications not listed in the description.

Fitment

Confirm compatibility with our team before ordering when your application is not listed.

Brand

MSD Ignition

MSD Ignition products are available from Engine Master Australia, supported by practical product knowledge and Australia-wide delivery.

Read more about MSD Ignition →

Warranty View information
Returns